Advertisement
Product › Details
GPC-AccuSpot-AXIMA MALDI-TOF system
![]() |
Next higher product group | time-of-flight mass spectrometer (TOF-MS) LC/MS system |
![]() |
Status | 2008-11-11 sales start |
![]() |
Organisation | Shimadzu Scientific Instruments Inc. (SSI) |
| Group | Shimadzu (Group) | |
Shimadzu Scientific Instruments, Inc.. (11/11/08). "Press Release: New Fully Automated GPC-MALDI System Reduces Analysis Time of Plastics and Synthetic Polymers".
Shimadzu Scientific Instruments introduces a gel permeation chromatography (GPC) mass spectrometer for quick analysis of ultra-trace substances such as impurities and additives in plastics and synthetic polymers. The GPC-AccuSpot-AXIMA combines a high resolution GPC system, the AccuSpot fully automated fraction collection and spotting device, and an AXIMA series MALDI-TOF mass spectrometer.
Until now, the steps for polymer and plastic analysis with GPC-MALDI required a tremendous amount of time and effort. To fully automate the process, Shimadzu redesigned their AccuSpot, a high-capacity liquid chromatography spotting system specifically designed for MS analysis, to make it compatible with standard GPC organic solvents. The device mixes the GPC eluent with MALDI matrix solution on-line and automatically deposits the resulting solution onto the MALDI sample target, resulting in improved efficiency and productivity.
With the GPC-AccuSpot-AXIMA system, researchers can automatically fraction a maximum of 384 1-µL samples of a separated sample. This eliminates the uncertainty associated with manual processing between separation by liquid chromatography and analysis by MALDI mass spectrometry. It also allows considerable time savings (from about 10 hours down to three hours). In addition, intelligent "Polymer Analysis" software calculates monomer unit molecular weight, end termini masses, polydispersity and average molecular weight.
The GPC-AccuSpot-AXIMA offers more detailed analysis of trace components that can not be detected due to ion suppression. It also helps detect substances that can affect material characteristics such as durability and deterioration.
Shimadzu is the only company that currently offers the complete system. However, the GPC-AccuSpot can be sold separately to be combined with an existing mass spectrometer.
Record changed: 2011-11-25 |
More documents for time-of-flight mass spectrometer (TOF-MS) LC/MS system
- [1] Virginia Tech. (12/17/11). Web Site: Chemistry Department > Mass Spec Laboratory. [http://www.chem.vt.edu, 12/17/11]...
- [2] [iito] Business Intelligence. (1/31/11). "[MSC] Newsletter January 2011". Bremen....
- [3] Waters Corporation. (1/10/11). "Press Release: Waters Combines Best-in-Class Performance, Versability and Usability Technologies in New Xevo G2 Tof Benchtop System". Milford, MA....
- [4] Waters Corporation. (1/10/11). "Press Release: Waters New Biopharmaceutical System Solution Uniquely Unites UPLC/MS Analyses and Workflows Driven by Industry First Scientific Information System". Milford, MA....
- [5] Universität Wuppertal. (5/11/10). Website. Analytischer Service im Fachbereich Chemie > Massenspektrometrie. [http://www.uni-wuppertal.de, 05/11/10]...
- [6] Agilent Technologies Inc.. (6/1/09). "Press Release: Owlstone and Agilent Technologies Collaborate to Explore FAIMS/TOF-MS Applications". Philadelphia....
- [7] Agilent Technologies Inc.. (03/09/09). "Press Release: Agilent Technologies, U.S. EPA Collaborate to Study Perfluorinated Compounds in Water, Wildlife". Chicago....
- [8] Agilent Technologies Inc.. (12/15/08). "Press Release: Agilent Technologies Introduces most Sensitive Time-of-Flight LC/MS ever. Agilent also Releases a 1600-pesticide Accurate Mass Database to Help Food Safety and Environmental Scientists Screen Pestici...
- [9] Waters Corporation. (6/3/05). "Press Release: Waters Mass Lynx™ Software Expands Information Management and Collaboration Capabilities". Milford, MA....
- [10] Bruker Daltonics, Inc.. (3/3/03). "Press Release: Bruker Daltonics Announces Novel High-Performance Benchtop ESI-TOF. New Research-grade Benchtop microTOF Features 2x Better Resolution and Mass Accuracy". Billerica, MA....
To subscribe to our free, monthly [MSC] Newsletter, please send an e-mail to info@iito.de and simply fill the subject line with the word »MSC newsletter«
To get even more information, please take a look at our [gs] professional services offering and read the gene-sensor Product Flyer [PDF file]
NEW: Visit our brand new forthcoming web portals Life-Sciences-Germany.com and Life-Sciences-Europe.com
» top
![[MSC] Mass-Spec-Capital.com The Mass Spectrometry Web Portal](/images/basics/msc-mass-spectrometry-portal-logo.jpg)








![Banner [iiito] Twitter iitoLifeScience Life Sciences Mass Spec 120x120px](/banner/iito-business-intelligence-20111029-120-120-twitter-iitolifescience-germany-europe-mass-spec.jpg)